BAL-FZ Roof & Wall Installations

Our team cover all areas of the Eastern States to carry out the fire protection installations of products and systems which meet the Flame Zone compliance requirements of Section 3 & Section 9 of:

Australian Standard AS3959-2018 Construction of Buildings in Bushfire-prone Areas.

Roof Elevations with a minimum setback distance of 10m from vegetation

A system tested to AS1530.8.2 which has achieved an FZ Classification (confirmed in a Report from a NATA Accredited Testing Authority) will be installed to the whole Roof, Fascia and Eave sections of these elevations. Or a system tested to AS1530.8.2 which has achieved an FZ Classification (confirmed in a Report from a NATA Accredited Testing Authority) will be installed to the Roof/Fascia & a system tested to AS1530.4-2014 & assessed IAW AS4072.1-2005 which has achieved an FRL of -/30/30 or 30/30/30 tested from outside/in (confirmed in a Report from a NATA Accredited Testing Authority) will be installed to the Eave sections.

Roof Elevations with a setback distance of less than 10m from vegetation

A system tested to AS1530.8.2 which has achieved an FZ Classification (confirmed in a Report from a NATA Accredited Testing Authority) will be installed to the whole Roof, Fascia and Eave sections of these elevations.

Wall Elevations with a minimum setback distance of 10m from vegetation

A system tested to AS1530.8.2 which has achieved an FZ Classification (confirmed in a Report from a NATA Accredited Testing Authority) will be installed to these Wall elevations. Or a system tested to AS1530.4-2014 & assessed IAW AS4072.1-2005 which has achieved an FRL of -/30/30 or 30/30/30 tested from outside/in (confirmed in a Report from a NATA Accredited Testing Authority) will be installed to these Wall Elevations.

Wall Elevations with a setback distance of less than 10m from vegetation

A system tested to AS1530.8.2 which has achieved an FZ Classification (confirmed in a Report from a NATA Accredited Testing Authority) will be installed to the Walls of these elevations.

Systems proven by test, offer the best protection for your homes & assets but only if they are installed by competent practitioners in strict accordance with the concise construction details contained within the reports from the NATA Accredited Testing Authorities.